|
|
Постановление Комитета по энергоэффективности при Совете Министров Республики Беларусь от 29.09.2006 N 2 "Об утверждении Методики по определению потерь тепловой энергии в сетях теплоснабжения с учетом их износа, срока и условий эксплуатации"(текст документа по состоянию на январь 2010 года. Архив) обновление Стр. 22 ¦ 76¦ 16 (14)¦ 23 (20)¦ 39 (34)¦ 34 (29)¦ 49 (42)¦ 40 (34)¦ 53 (46)¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 89¦ 17 (15)¦ 25 (22)¦ 42 (37)¦ 36 (31)¦ 52 (45)¦ 44 (38)¦ 58 (50)¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 108¦ 19 (16)¦ 28 (24)¦ 47 (40)¦ 41 (35)¦ 58 (50)¦ 48 (41)¦ 63 (54)¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 133¦ 21 (18)¦ 31 (27)¦ 52 (45)¦ 42 (36)¦ 60 (52)¦ 50 (43)¦ 66 (57)¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 159¦ 22 (19)¦ 32 (28)¦ 54 (47)¦ 44 (38)¦ 63 (54)¦ 55 (47)¦ 72 (62)¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 219¦ 27 (23)¦ 39 (34)¦ 66 (57)¦ 54 (46)¦ 76 (65)¦ 68 (58)¦ 89 (77)¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 273¦ 30 (26)¦ 45 (39)¦ 75 (65)¦ 64 (55)¦ 89 (77)¦ 77 (66)¦ 100 (86)¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 325¦ 33 (28)¦ 50 (43)¦ 83 (71)¦ 70 (60)¦ 98 (84)¦ 84 (72)¦ 109 (94)¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 377¦ 37 (32)¦ 55 (47)¦ 92 (79)¦ 75 (65)¦ 105 (90)¦ 94 (81)¦120 (103)¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 426¦ 38 (33)¦ 58 (50)¦ 96 (83)¦ 82 (71)¦ 115 (99)¦101 (87)¦129 (111)¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 478¦ 43 (37)¦ 67 (57)¦ 110 (94)¦ 93 (80)¦129 (111)¦107 (92)¦136 (117)¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 529¦ 44 (38)¦ 68 (58)¦ 112 (96)¦ 98 (84)¦136 (117)¦ 117 ¦149 (128)¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦ (101)¦ ¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 630¦ 50 (43)¦ 79 (68)¦129 (111)¦109 (94)¦150 (129)¦ 132 ¦166 (143)¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦ (114)¦ ¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 720¦ 55 (47)¦ 89 (77)¦144 (124)¦ 126 ¦169 (145)¦ 151 ¦188 (162)¦ ¦ ¦ ¦ ¦ ¦ (108)¦ ¦ (130)¦ ¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 820¦ 60 (52)¦100 (86)¦160 (138)¦ 140 ¦185 (159)¦ 163 ¦203 (175)¦ ¦ ¦ ¦ ¦ ¦ (120)¦ ¦ (140)¦ ¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 920¦ 66 (57)¦106 (91)¦172 (148)¦ 151 ¦205 (176)¦ 186 ¦229 (197)¦ ¦ ¦ ¦ ¦ ¦ (130)¦ ¦ (160)¦ ¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 1020¦ 71 (61)¦ 117 ¦188 (162)¦ 158 ¦215 (185)¦ 192 ¦239 (206)¦ ¦ ¦ ¦ (101)¦ ¦ (136)¦ ¦ (165)¦ ¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 1220¦ 79 (68)¦ 144 ¦223 (192)¦ 185 ¦249 (214)¦ 229 ¦281 (242)¦ ¦ ¦ ¦ (124)¦ ¦ (159)¦ ¦ (197)¦ ¦ +--------+--------+--------+---------+--------+---------+--------+---------+ ¦ 1420¦ 82 (71)¦ 152 ¦234 (202)¦ 210 ¦278 (239)¦ 252 ¦308 (265)¦ ¦ ¦ ¦ (131)¦ ¦ (181)¦ ¦ (217)¦ ¦ ¦--------+--------+--------+---------+--------+---------+--------+---------- ------------------------------- Д - греческая буква "дельта" Примечания: 1. Нормы плотности теплового потока определены из таблицы 2 приложения 7 СНиП 2.04.14-88 "Тепловая изоляция оборудования и трубопроводов", утв. Постановлением Государственного строительного комитета СССР от 9 августа 1988 г. N 155, изданы Госстроем СССР, Москва, 1989 г., введены в действие 1 января 1990 г. 2. Для участков тепловых сетей, сооруженных по проектам, выполненным после 1 июля 1995 г., к табличным значениям вводится коэффициент K = 0,7 (Изменение N 1 к СНиП 2.04.14-88, введенное Т1 постановлением Государственного комитета Республики Беларусь по строительству и архитектуре N 67 от 17 марта 1995 г.). 3. В нормах суммарно для двухтрубной прокладки учтено влияние одного трубопровода на другой. Приложение Д (обязательное) Таблица Д.1 - НОРМЫ ПЛОТНОСТИ ТЕПЛОВОГО ПОТОКА ЧЕРЕЗ ИЗОЛИРОВАННУЮ ПОВЕРХНОСТЬ ТРУБОПРОВОДОВ ПРИ ДВУХТРУБНОЙ ср.г ПОДЗЕМНОЙ БЕСКАНАЛЬНОЙ ПРОКЛАДКЕ С т = +5 ГРАД. C гр.р НА ГЛУБИНЕ ЗАЛОЖЕНИЯ ОСИ ТРУБОПРОВОДОВ ДЛЯ ТЕПЛОВЫХ СЕТЕЙ СО СРОКОМ ВВОДА В ЭКСПЛУАТАЦИЮ С 1994 Г. С ЧИСЛОМ ЧАСОВ РАБОТЫ В ГОД БОЛЕЕ 5000 ------------------------------- т - греческая буква "тау" Вт/м (ккал/м·ч) ---------+--------+----------+----------+------------+-------------¬ ¦Наружный¦ Для ¦ Для ¦Суммарные ¦ Для ¦ Суммарные ¦ ¦диаметр ¦обратной¦ подающей ¦ для 2-х ¦ подающей ¦ для 2-х ¦ ¦ труб, ¦ линии ¦ линии ¦ трубной ¦ линии ¦ трубной ¦ ¦ d , мм ¦ t = 50¦ t = 65 ¦прокладки ¦ t = 90 ¦ прокладки ¦ ¦ н ¦ 2 ¦ 1 ¦Дt = 52,5 ¦ 1 ¦ Дt = 65 ¦ ¦ ¦ град. C¦ град. C ¦ град. C ¦ град. C ¦ град. C ¦ ¦ ¦ Дt = 45¦ Дt = 60 ¦ ¦ Дt = 85 ¦ ¦ ¦ ¦ град. C¦ град. C ¦ ¦ град. C ¦ ¦ +--------+--------+----------+----------+------------+-------------+ ¦ 32¦ 25 (22)¦ 33 (28)¦ 58 (50)¦ 44 (38)¦ 68 (58)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 57¦ 31 (27)¦ 40 (34)¦ 71 (61)¦ 54 (46)¦ 83 (72)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 76¦ 34 (29)¦ 45 (39)¦ 79 (68)¦ 60 (51)¦ 93 (80)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 89¦ 35 (30)¦ 46 (40)¦ 81 (70)¦ 61 (52)¦ 95 (82)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 108¦ 38 (33)¦ 49 (42)¦ 87 (75)¦ 65 (56)¦ 100 (86)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 133¦ 41 (35)¦ 53 (46)¦ 94 (81)¦ 72 (62)¦ 111 (95)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 159¦ 46 (40)¦ 60 (52)¦ 106 (92)¦ 80 (69)¦ 123 (106)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 219¦ 50 (43)¦ 66 (57)¦ 116 (100)¦ 89 (77)¦ 137 (118)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 273¦ 55 (47)¦ 72 (62)¦ 127 (109)¦ 96 (83)¦ 147 (126)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 325¦ 59 (51)¦ 79 (68)¦ 138 (119)¦ 105 (90)¦ 161 (138)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 377¦ 65 (56)¦ 86 (74)¦ 151 (130)¦ 113 (97)¦ 173 (149)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 426¦ 68 (58)¦ 91 (78)¦ 159 (136)¦ 121 (104)¦ 184 (158)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 478¦ 72 (62)¦ 97 (83)¦ 169 (145)¦ 129 (111)¦ 196 (169)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 529¦ 78 (67)¦ 105 (90)¦ 183 (157)¦ 138 (119)¦ 210 (181)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 630¦ 87 (75)¦ 117 (101)¦ 204 (176)¦ 156 (134)¦ 236 (203)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 720¦ 93 (80)¦ 126 (108)¦ 219 (188)¦ 170 (146)¦ 256 (220)¦ +--------+--------+----------+----------+------------+-------------+ ¦ 820¦102 (88)¦ 140 (120)¦ 242 (208)¦ 186 (160)¦ 279 (240)¦ ¦--------+--------+----------+----------+------------+-------------- ------------------------------- Д - греческая буква "дельта" Примечания: 1. Нормы плотности теплового потока определены из таблицы 2 приложения 8 СНиП 2.04.14-88 "Тепловая изоляция оборудования и трубопроводов", утв. Постанов-лением Государственного строительного комитета СССР от 9 августа 1988 г. N 155, изданы Госстроем СССР, Москва, 1989 г., введены в действие 1 января 1990 г. 2. Для участков тепловых сетей, сооруженных по проектам, выполненным после 1 июля 1995 г., к табличным значениям вводится коэффициент K = 0,8 (Изменение N 1 СНиП 2.04.14-88, введенное Т1 постановлением Государственного комитета Республики Беларусь по строительству и архитектуре N 67 от 17 марта 1995 г.) 3. При. применении в качестве теплоизоляционного слоя пенополиуритана, фенольного поропласта ФЛ, полимербетона значения норм плотности теплового потока следует определять с учетом коэффициента K (из таблицы 3 приложения 8 СНиП 2.04.14-88). Т2 ------------------------------+------------------------------------¬ ¦ Материал изоляционного слоя ¦ Наружный диаметр трубопровода, мм ¦ ¦ +-------+--------+---------+---------+ ¦ ¦32 - 76¦89 - 159¦219 - 325¦377 - 529¦ ¦ +-------+--------+---------+---------+ ¦ ¦ Коэффициент K ¦ ¦ ¦ Т2 ¦ +-----------------------------+-------+--------+---------+---------+ ¦Пенополиуретан, ¦ ¦ ¦ ¦ ¦ ¦фенольпоропласт ФЛ ¦ 0,5 ¦ 0,6 ¦ 0,7 ¦ 0,8 ¦ +-----------------------------+-------+--------+---------+---------+ ¦Полимербетон ¦ 0,7 ¦ 0,8 ¦ 0,9 ¦ 1,0 ¦ ¦-----------------------------+-------+--------+---------+---------- 4. В нормах суммарно для двухтрубной прокладки учтено влияние одного трубопровода на другой. Приложение Е (обязательное) Таблица Е.1 - НОРМЫ ПЛОТНОСТИ ТЕПЛОВОГО ПОТОКА ЧЕРЕЗ ИЗОЛИРОВАННУЮ ПОВЕРХНОСТЬ ТРУБОПРОВОДОВ ПРИ ДВУХТРУБНОЙ ср.г ПОДЗЕМНОЙ БЕСКАНАЛЬНОЙ ПРОКЛАДКЕ С т = +5 ГРАД. C гр.р НА ГЛУБИНЕ ЗАЛОЖЕНИЯ ТРУБОПРОВОДОВ ДЛЯ ТЕПЛОВЫХ СЕТЕЙ СО СРОКОМ ВВОДА В ЭКСПЛУАТАЦИЮ С 1994 Г. С ЧИСЛОМ ЧАСОВ РАБОТЫ В ГОД 5000 И МЕНЕЕ ------------------------------- т - греческая буква "тау" Вт/м (ккал/м·ч) ---------+---------+----------+----------+------------+------------¬ ¦Наружный¦ Для ¦ Для ¦Суммарные ¦ Для ¦ Суммарные ¦ ¦диаметр ¦ обратной¦ подающей ¦ для 2-х ¦ подающей ¦ для 2-х ¦ ¦ труб, ¦ линии ¦ линии ¦ трубной ¦ линии ¦ трубной ¦ ¦ d , мм ¦ t = 50 ¦ t = 65 ¦прокладки ¦ t = 90 ¦ прокладки ¦ ¦ н ¦ 2 ¦ 1 ¦Дt = 52,5 ¦ 1 ¦ Дt = 65 ¦ ¦ ¦ град. C ¦ град. C ¦ град. C ¦ град. C ¦ град. C ¦ ¦ ¦ Дt = 45 ¦ Дt = 60 ¦ ¦ Дt = 85 ¦ ¦ ¦ ¦ град. C ¦ град. C ¦ ¦ град. C ¦ ¦ +--------+---------+----------+----------+------------+------------+ ¦ 32¦ 27 (23)¦ 36 (31)¦ 63 (54)¦ 48 (41)¦ 74 (64)¦ +--------+---------+----------+----------+------------+------------+ ¦ 57¦ 34 (29)¦ 44 (38)¦ 78 (67)¦ 60 (52)¦ 92 (79)¦ +--------+---------+----------+----------+------------+------------+ ¦ 76¦ 38 (33)¦ 50 (43)¦ 88 (76)¦ 67 (58)¦ 103 (89)¦ +--------+---------+----------+----------+------------+------------+ ¦ 89¦ 39 (34)¦ 51 (44)¦ 90 (77)¦ 69 (59)¦ 106 (91)¦ +--------+---------+----------+----------+------------+------------+ ¦ 108¦ 42 (36)¦ 55 (47)¦ 97 (83)¦ 74 (64)¦ 114 (98)¦ +--------+---------+----------+----------+------------+------------+ ¦ 133¦ 46 (40)¦ 61 (52)¦ 107 (92)¦ 81 (70)¦ 125 (108)¦ |
Партнеры
|